Sign In | Join Free | My pysqlite.org
pysqlite.org
Hunan Leading Science and Technology Development Co.,Ltd
Leading Science & Technology, always leading the technology of pump control and protection technology
Home > Sewage Pump Control Panel >

L922-S Duplex Pump Control Panel For Control & Protect Sewage / Drainage Pump

Hunan Leading Science and Technology Development Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Hunan Leading Science and Technology Development Co.,Ltd
City: Changsha
Province/State: Hunan
Country/Region: China
Tel: 86-731-84471500
Contact Person:
Mr Steven Ma

L922-S Duplex Pump Control Panel For Control & Protect Sewage / Drainage Pump

Brand Name : Leading
Model Number : L922-S
Certification : CE
Place of Origin : CHINA
MOQ : 1 set
Price : Negotiable
Payment Terms : L/C, D/P, T/T
Supply Ability : 10000 sets Per Month
Delivery Time : 15-30 days
Packaging Details : Carton
Rated output power : 0.37KW-2.2KW (0.5HP-3HP)
Rated input voltage : AC220V/50HZ Single Phase
Trip response time of over load : 5sec-5min
Trip response time of short circuit : <0.1sec
Trip response time of under / over voltage : <5sec
Trip response time of dry run : 6sec
Recovery time of over load : 30min
Recovery time of under / over voltage : 5min
Recovery time of dry run : 30min
Trip voltage of over voltage : 253V
Trip voltage of under voltage : 175V
Contact Now

Intelligent Single Phase Sewage Pump Controller - Auto And Manual,0.37-2.2KW

Model: L922-S

Products Brief :


Model L922/S is specially designed for sewage pumping system, by adopting level transmitter with 0.5-4.5V analog signal, pump user can easily set the different liquid depth for sewage pump operation and observe the dynamic liquid depth in the sump or sewage tank.


Typical usage scenarios include:

- Houses  - Flats

- Holidays houses  - Farms

- Industrial plants  - Construction site


Main Technical Specifications


Rated Input Voltage…………………………………………………AC220V / Single Phase

■ Rated Frequency………………………………………………….……50Hz-60Hz (at option)

■ Rated Output Power of Motor……………………………0.37-2.2KW / 3-4KW(at option)

■ Short Circuit Trip Response Time……………………………………………………0.1sec

■ Dry Running Trip Response Time………………………………………………...... 6sec

■ Over / Under Voltage Trip Response Time……………………………………….….5sec

■ Pump Stalled Trip Response Time……………………..…………………………......0.5sec

■ Over Current Trip Response Time………………………………………………5sec-5min

■ Recovery Time of Over / Under Voltage………………………………………..…….…2min

■ Recovery Time of Over Current…………………………………………………….…30min

■ Recovery Time of Dry Running.………………………………………………….…30min

■ Over / Under Voltage Trip……..……………………………….………………….….…±15%

■ Dry Running Trip……………………………………………….………………….…….….70%

■ Pump Stalled Trip………………………………………….……………………………..200%


① the Characteristic of Inverse-time, the stronger of the current, The shorter of trip response time)

② Percent of rated input voltage ( i.e if the rated input voltage is 220V, the Over voltage trip is

253V, the Under voltage trip is 187V)

③ Percent of load time of calibration ( i.e if the running ampere of pump motor is 6A during the

calibration, the dry running trip ampere is 4.2A)

④ Percent of load time of calibration ( i.e if the running ampere of pump motor is 6A during the calibration, The pump stalled trip ampere is 12A)


ApplicationControl & protect sewage / drainage pump only
ModelL922-S
Main technical data
.Start typeDirect on line
. Qty of controlled pumpDuplex pump
. Rated input voltage:

AC220V-240V Single phase

50HZ/ 60HZ

. Rated output power:

0.37kw-2.2kw (0.5hp-3hp)

3-4kw(4hp-5.5hp)


Protection function

Over load protection

Pump stalled protection

Dry run protection

Under voltage protection

Repeat start protection



Control characteristic

Connecting 0.5-4.5V level transmitter to replace float switch or level probe

Duplex pump control

.Main pump / standby pump automatically alternate

.Main pump / standby pump automatically switch against malfunction

.Standby pump participate running if required


Other features

LCD screen displaying dynamic real time depth & pump running status

Pump shaft anti-rusty

Pump accumulative running time recording

Pump last five faults recording displaying

Presenting one dry contact point (BA port)

Present RS485 port

Present user remote monitor

LCD screen locked function under Auto state

Push button calibration

Main installation data

Working temperature

Working humidity

Degree of protection

Install position

Unit dimension (L x W x H)

-25℃-- +55℃

20%--90%RH, no drips concreted

IP54

Wall mounting

310 x 220x 1 20mm



Product Tags:

sewage pump controller

      

sewer pump control panel

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

L922-S Duplex Pump Control Panel For Control & Protect Sewage / Drainage Pump Images

Inquiry Cart 0
Send your message to this supplier
 
From:
Enter your email please.
To: Hunan Leading Science and Technology Development Co.,Ltd
Subject:
Message:
Characters Remaining: (0/3000)
 

Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

Copyright © 2009 - 2018 pysqlite.org. All rights reserved.